Air Flow Capture Hood in this system DBM 610 series can cause and used for multi purpose as it carries electronic air balancing device or instrument this could effect system reliability and will allow to control and balance in flow of air conditioning system which is became the most common scenario for every to see and use it for properly taking direct air volume readings at diffusers and grilles. The air flow capture hood DBM610 series are available for used to allows balancing and controlling of airflow in an air conditioning system. The main features of DBM610 is: DBM610 is mainly used on any kind of diffusers in air deplete. It features a removable micro manometer for increased flexibility in multiple measurement applications. It is very easy to handle, light-weight, it allows for correct, robust and rapid measurements. Because of it is Providing durable operation, this light-weight, ease and comfort designed Airflow capture hood kit or set saves time and money by combining multiple measurement instruments into one package. It is supplied standard with a 2 x 2 feet hood and four other sizes are available as options.
The Independent Micro-manometer can be taken out from the primary device and is capable of: Concurrent display of airflow and temperature; Automatic airflow path(extraction or air blast); Automatic averaging or point by point calculating; Hold function; and Data processing on PC with Universal serial bus port with different languages are also available.
Applications:
Air flow capture hood is can be used for HVAC testing, adjusting and balancing the air flow
Air flow volume measurements through registers, diffusers in air deplete
It can be Direct readout at supply and return airflow
Capture hood has capacity to measure Air velocity in the duct
Check filter fouling by calibrating differential pressure
Features include:
Measuring ranges of DBM610 capture hood get started from 17 CFM to 2060 CFM which is really good for user
Software program for data processing on computer
Durable, light in weight and easy to use and handle
Detachable measuring unit
Compatible hoods
It includes hood of 2 x 2 feet dimensions with a good transport case and this series has calibration certificate.
Air Flow Capture hood in Accuracy of this product is 3% of measuring +/- 10 m3/h, Resolution is 1 m3/h, Temperature Measuring Range from 32 to 140°F (0 to 60°C), Pressure (on the micro-manometer) range from -10 to 10 in Wg (-2500 to +2500 Pa), Resolution in between 0.01 to 0.1 Pa
You May Also Like:
Linear Displacement Transmitter
Moisture in Oil Transmitter
Air Velocity Transmitter
Pressure Transmitter Gauge
The Independent Micro-manometer can be taken out from the primary device and is capable of: Concurrent display of airflow and temperature; Automatic airflow path(extraction or air blast); Automatic averaging or point by point calculating; Hold function; and Data processing on PC with Universal serial bus port with different languages are also available.
Applications:
Air flow capture hood is can be used for HVAC testing, adjusting and balancing the air flow
Air flow volume measurements through registers, diffusers in air deplete
It can be Direct readout at supply and return airflow
Capture hood has capacity to measure Air velocity in the duct
Check filter fouling by calibrating differential pressure
Features include:
Measuring ranges of DBM610 capture hood get started from 17 CFM to 2060 CFM which is really good for user
Software program for data processing on computer
Durable, light in weight and easy to use and handle
Detachable measuring unit
Compatible hoods
It includes hood of 2 x 2 feet dimensions with a good transport case and this series has calibration certificate.
Air Flow Capture hood in Accuracy of this product is 3% of measuring +/- 10 m3/h, Resolution is 1 m3/h, Temperature Measuring Range from 32 to 140°F (0 to 60°C), Pressure (on the micro-manometer) range from -10 to 10 in Wg (-2500 to +2500 Pa), Resolution in between 0.01 to 0.1 Pa
You May Also Like:
Linear Displacement Transmitter
Moisture in Oil Transmitter
Air Velocity Transmitter
Pressure Transmitter Gauge
0 comments:
Post a Comment